FLAMEPROOF TUBE LIGHT FITTINGS
| (A) EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & II B. |
| Cat. No. |
Description. |
| FF/OA/1271 |
Upto 40 Watt Single/Twin Tubes with or without Reflector and Wire guards with relamping arrangement. |
| FF/OA/1271 |
Upto 36W PL Lamps Single/Twin with or without Reflector and wireguard with relamping arrangement (NEW). |
| FF/A/127 |
Upto 40Watts Single/Twin Tubes with or without Reflector and wire guard with relamping arrangement (with DGMS approval for Oil Mines). |
(B) EX-e Increased Safety for Zone 2 (WP) |
| DTL/A/161 |
Upto 40 Watts Single/Twin Tubes with or without Reflector and Wire guards. |
Note : For Zone 2 equipments can be used in all gas groups II A, II B & II C. |
(C) DUST TIGHT DUSTPROOF. |
| DTL/A/161 |
Upto 40 Watts Single/Twin Tubes with or without Reflector and Wire guard. |
FLAMEPROOF WELLGLASS FITTING
| Cat No |
Description |
|
|
| WG/OA/1231 |
Upto 125 W HPMV/160 W MLL/ 200 W GLS Lamp with indirect entry. |
|
|
| WG/OA/1233 |
Upto 125 W HPMV/160 W MLL/ 200 W GLS Lamp with Front Openable Cover |
|
|
| WG/OA/1233 |
Upto 125 W HPMV with Built In Epoxy Choke with Front Openable Cover |
|
|
| WG/OA/1234 |
Upto 250 W HPMV / 250 W MLL / 300 W GLS Lamp with Cable Box. |
|
|
| WG/OA/1234 |
Upto 125 W HPMV with Built in Controlgear Box with Cable Box. |
|
|
| WG/OA/1235 |
250 W HPMV Lamp with Built in Controlgear Box. |
|
|
| WG/OA/1236 |
400 W HPMV Lamp. |
|
|
| WG/OOA/122 |
Upto 125 W HPMV / 160 W MLL / 200 W GLS Lamp with Front Operable Cover.(with DGMS approval for Oil mines ) |
|
|
| WG/OA/1234 |
For Twin / Three Nos. PL Lamps upto 26 W for Power Saving. |
|
|
NOTE :-
|
(1)Cat. No. WG/A/1231 & WG/OA/1234 fittings are also available with threaded joints.
|
|
(2)Wellglasses are also available for Halogen Lamps and other Lamps.
|
(B) Ex-d Explosionsproof for Zone 1 & 2 Gas Group II C FLP/WP. |
| Cat No |
Description |
| WG/2C/1234 |
Upto 250 W HPMV / 300 W GLS / 160 - 250 W MLL Lamp. |
| WG/2C/1234 |
Upto 125 W HPMV with Built in Controlgear Box. |
| EX-C |
|
(C)Ex-e Increased Safety for Zone 2 WP. |
| Cat. No. |
Description. |
| WG/182 |
Upto 250W HPMV/250 W MLL / 300 W GLS Lamp / 150 W HPSV Lamp. |
| WG/182 |
Upto 125 W HPMV / 70 W HPSV Lamps with Built-in- Controlgear Box. |
| WG/185 |
Upto 125W HPMV/160W MLL/200W GLS/70 W HPSV Lamp. |
| WG/192 |
Upto 125W HPMV/160W MLL/200W GLS with Threaded Design. |
NOTE:- |
| (1) |
FOR Zone 2 equipments can be used in all gas groups II A, II B & IIC. |
(D) DUST TIGHT DUSTPROOF. |
| Cat. No. |
Description. |
| WG/DT/GEN/IND/154 |
Upto 125W HPMV/160W MLL/200W GLS/70W HPSV Lamp. |
| WG/DT/MVP/COM/154-W |
Upto 125W HPMV/70W HPSV with Built-in-Controlgear Box. |
FLAMEPROOF BULKHEAD FITTING
| EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB. |
| Cat. No. |
Description. |
|
| BH/OA/124 |
FLP upto 125W HPMV/160W MLL/200W GLS Lamp. |
|
| BH/OA/124 |
FLP upto 3 Nos. 11/13W PL Lamps with Built in Choke for Power Saving. |
BH/OA/124 |
| BH/OA/184 |
FLP-WP IP55 upto 125W HPMV/160W MLL/200W GLS Lamp. |
 BH/OA/184 |
FLAMEPROOF FLOODLIGHT FITTING
| EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & II B (FLP-WP) |
|
| Cat. No. |
Description. |
|
| FL/A/150 |
Upto 125W HPMV/160W MLL/200W GLS Lamp. |
|
| FL/OA/151 |
Upto 250W HPMV/250W MLL/300W GLS Lamp. |
|
| FL/1251 |
Upto 400W HPMV/500W GLS Lamp (NEW). |
|
| FL/A/125 |
Upto 400W HPMV/500W GLS Lamp. |
|
NOTE :- Fittings for Halogen Lamps also available. |
|
FLAMEPROOF HAND LAMP
| EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & IIB (FLP-WP) |
| Cat. No. |
Description. |
| HL/OA/126 |
Upto 60W GLS Lamp 24V/240V with Threaded Joints. |
| |
|
| HL/OA/183 |
Upto 60W GLS Lamp 24V/240V with Spigotted Joints. |
NOTE :- Fittings for Halogen Lamps also available. |
FLAMEPROOF VESSEL LAMP
| EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & IIB (FLP-WP) |
| Cat. No. |
Description. |
| RVL/A/128 |
Upto 100W GLS Lamp with/without Switch with Threaded Joints. |
| RVL/A/181 |
Upto 100W GLS Lamp with/without Switch with Spigotted Joints. |
| RVL/OA/1601 |
Upto 100W GLS Lamp Spigotted Joints.PCD 246 mm |
NOTE :- Vessel Lamp for Halogen Lamp and 200W GLS Lamp also available. |
FLAMEPROOF EMERGENCY TUBE LIGHT FITTING.
| EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB (FLP-WP). |
| Cat. No. |
Description. |
| ETL/OA/163 |
For 20W Tube with Rechargeable dry type Battery And circuit with wire guard. |
| NOTE :- For other Wattages details on request. |
FLAMEPROOF TORCH
| Intrinsically Safe (Ex-ia) for Zone 1 * 2 Gas Groups II A & IIB. |
| Cat. No. |
Description. |
| TCH/OB/180 |
Suitable for Cell/3 Cell 3V/4.5V dry type batteries In Brass Construction. |
FLAMEPROOF PORTABLE HAND LAMP
| Intrinsically Safe (Ex-ia) for Zone 1 & 2 Gas Groups II A & IIB. |
| Cat. No. |
Description. |
| ETL/184 |
For Hand Lamp (with rechargeable dry type battery And circuit in safe area). |
NOTE :- Light Fittings for other type of Bulbs/Tubes and Ex-d for Group IIC are constantly under development/approval. For details please check with us |
FLAMEPROOF CONTROL GEAR BOX
| (A) Ex-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB 9FLP-WP) |
| Cat. No. |
Description |
| CGB/OA/174 |
For 80/125W HPMV Lamp |
| CGB/A/130 |
For 250 W HPMV Lamp. |
| CGB/A/131 |
For 400 W HPMV Lamp. |
(B) Ex-d Explosionproof for Zone 1 & 2 Gas Groups II C (FLP-WP) |
| Cat. No. |
Description |
| CGB/2C/130 |
For 80/125/250W HPMV Lamp. |
(C) Ex-d Increased Safety for Zone 2 (WP) |
| Cat. No. |
Description |
| WG/DII/MVP/IND/158 |
For 80/125W HPMV or 70W HPSV Lamp. |
| CGB/202 |
For 250W HPMV/150W HPSV Lamp. |
(D) DUST TIGHT DUSTPROOF |
| Cat. No. |
Description |
| WG/DT/MVP/COM/154 |
For 80/125W HPMV Lamp. |
FLAMEPROOF FANS - EXHAUST, CIELING, PEDESTAL & WALL MOUNTING
| EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB |
Explosion proof of complete fan alongwith motor is certified by C M R I Dhanbad. |
(A) CEILING FAN : FIRST TIME IN INDIA. |
| SUDHIR has developed First Time in India CEILING CAN suitable for Single Phase 240V AC supply in cast aluminium alloy LM6 construction light weight blade size upto 48". Cat. No. CF/193 |
(B) EXHAUST FANS: |
| Cat. No. EF/140 Single/Three Phase Size 9" to 24". |
(C) WALL MOUNTING FANS : |
| Cat. No. WMF/140 Single/Three Phase Size 16" to 36". |
(D) DEDESTAL FANS : |
| Cat. No. PF/140 |
Aircirculators/Mancoolers single/three phase size 12" to 36". |
NOTE :- Fans with FRP Coating Stainless Steel Wire Guards, Blades or Specific application are also available. |
|