FLAMEPROOF TUBE LIGHT FITTINGS

(A) EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & II B.
Cat. No. Description.
FF/OA/1271  Upto 40 Watt Single/Twin Tubes with or without Reflector and Wire guards with relamping arrangement. 
FF/OA/1271  Upto 36W PL Lamps Single/Twin with or without Reflector and wireguard with relamping arrangement (NEW). 
FF/A/127 Upto 40Watts Single/Twin Tubes with or without Reflector and wire guard with relamping arrangement (with DGMS approval for Oil Mines).

(B) EX-e Increased Safety for Zone 2 (WP)
DTL/A/161 Upto 40 Watts Single/Twin Tubes with or without Reflector and Wire guards. 

Note : For Zone 2 equipments can be used in all gas groups II A, II B & II C. 

(C) DUST TIGHT DUSTPROOF.
DTL/A/161 Upto 40 Watts Single/Twin Tubes with or without Reflector and Wire guard. 

 


 FLAMEPROOF WELLGLASS FITTING 

Cat No  Description
WG/OA/1231 Upto 125 W HPMV/160 W MLL/ 200 W GLS Lamp with indirect entry.
WG/OA/1233 Upto 125 W HPMV/160 W MLL/ 200 W GLS Lamp with Front Openable Cover 
WG/OA/1233 Upto 125 W HPMV with Built In Epoxy Choke with Front Openable Cover
WG/OA/1234 Upto 250 W HPMV / 250 W MLL / 300 W GLS Lamp with Cable Box.
WG/OA/1234 Upto 125 W HPMV with Built in Controlgear Box with Cable Box.
WG/OA/1235 250 W HPMV Lamp with Built in Controlgear Box.
WG/OA/1236 400 W HPMV Lamp.
WG/OOA/122 Upto 125 W HPMV / 160 W MLL / 200 W GLS Lamp with Front Operable Cover.(with DGMS approval for Oil mines )
WG/OA/1234 For Twin / Three Nos. PL Lamps upto 26 W for Power Saving.

NOTE :-

(1)Cat. No. WG/A/1231 & WG/OA/1234 fittings are also available with threaded joints.
(2)Wellglasses are also available for Halogen Lamps and other Lamps. 

(B) Ex-d Explosionsproof for Zone 1 & 2 Gas Group II C FLP/WP.
Cat No  Description
WG/2C/1234 Upto 250 W HPMV / 300 W GLS / 160 - 250 W MLL Lamp.
WG/2C/1234 Upto 125 W HPMV with Built in Controlgear Box.
EX-C

(C)Ex-e Increased Safety for Zone 2 WP.
Cat. No.  Description.
WG/182 Upto 250W HPMV/250 W MLL / 300 W GLS Lamp / 150 W HPSV Lamp. 
WG/182 Upto 125 W HPMV / 70 W HPSV Lamps with Built-in- Controlgear Box. 
WG/185 Upto 125W HPMV/160W MLL/200W GLS/70 W HPSV Lamp. 
WG/192  Upto 125W HPMV/160W MLL/200W GLS with Threaded Design. 

NOTE:-
(1) FOR Zone 2 equipments can be used in all gas groups II A, II B & IIC. 

(D) DUST TIGHT DUSTPROOF.
Cat. No. Description.
WG/DT/GEN/IND/154 Upto 125W HPMV/160W MLL/200W GLS/70W HPSV Lamp.
WG/DT/MVP/COM/154-W Upto 125W HPMV/70W HPSV with Built-in-Controlgear Box.


FLAMEPROOF BULKHEAD FITTING 

EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB.
Cat. No. Description.  
BH/OA/124  FLP upto 125W HPMV/160W MLL/200W GLS Lamp.   
BH/OA/124  FLP upto 3 Nos. 11/13W PL Lamps with Built in Choke for Power Saving. BH/OA/124 
BH/OA/184 FLP-WP IP55 upto 125W HPMV/160W MLL/200W GLS Lamp. 
BH/OA/184


FLAMEPROOF FLOODLIGHT FITTING

EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & II B (FLP-WP)
Cat. No. Description.
FL/A/150 Upto 125W HPMV/160W MLL/200W GLS Lamp.
FL/OA/151 Upto 250W HPMV/250W MLL/300W GLS Lamp.
FL/1251 Upto 400W HPMV/500W GLS Lamp (NEW).
FL/A/125 Upto 400W HPMV/500W GLS Lamp.

NOTE :-
Fittings for Halogen Lamps also available.


 FLAMEPROOF HAND LAMP

EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & IIB (FLP-WP)
Cat. No. Description.
HL/OA/126 Upto 60W GLS Lamp 24V/240V with Threaded Joints.
 
HL/OA/183 Upto 60W GLS Lamp 24V/240V with Spigotted Joints.

NOTE :-
Fittings for Halogen Lamps also available.


FLAMEPROOF VESSEL LAMP

EX-d Explosionproof for Zone 1 & 2 Gas Groups II A & IIB (FLP-WP)
Cat. No. Description.
RVL/A/128 Upto 100W GLS Lamp with/without Switch with Threaded Joints.
RVL/A/181 Upto 100W GLS Lamp with/without Switch with Spigotted Joints.
RVL/OA/1601 Upto 100W GLS Lamp Spigotted Joints.PCD 246 mm

NOTE :-
Vessel Lamp for Halogen Lamp and 200W GLS Lamp also available.


 FLAMEPROOF EMERGENCY TUBE LIGHT FITTING.

EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB (FLP-WP).
Cat. No. Description.
ETL/OA/163 For 20W Tube with Rechargeable dry type Battery And circuit with wire guard.
NOTE :- For other Wattages details on request.


 FLAMEPROOF TORCH

Intrinsically Safe (Ex-ia) for Zone 1 * 2 Gas Groups II A & IIB.
Cat. No. Description.
TCH/OB/180 Suitable for Cell/3 Cell 3V/4.5V dry type batteries In Brass Construction.


FLAMEPROOF PORTABLE HAND LAMP

Intrinsically Safe (Ex-ia) for Zone 1 & 2 Gas Groups II A & IIB.
Cat. No. Description.
ETL/184 For Hand Lamp (with rechargeable dry type battery And circuit in safe area).

NOTE :-
Light Fittings for other type of Bulbs/Tubes and Ex-d for Group IIC are constantly under development/approval. For details please check with us


 

FLAMEPROOF CONTROL GEAR BOX

(A) Ex-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB 9FLP-WP)
Cat. No. Description
CGB/OA/174 For 80/125W HPMV Lamp
CGB/A/130 For 250 W HPMV Lamp.
CGB/A/131 For 400 W HPMV Lamp.

(B) Ex-d Explosionproof for Zone 1 & 2 Gas Groups II C (FLP-WP)
Cat. No. Description
CGB/2C/130 For 80/125/250W HPMV Lamp.

(C) Ex-d Increased Safety for Zone 2 (WP)
Cat. No. Description
WG/DII/MVP/IND/158 For 80/125W HPMV or 70W HPSV Lamp.
CGB/202 For 250W HPMV/150W HPSV Lamp.

(D) DUST TIGHT DUSTPROOF
Cat. No. Description
WG/DT/MVP/COM/154 For 80/125W HPMV Lamp.


 

FLAMEPROOF FANS - EXHAUST, CIELING, PEDESTAL & WALL MOUNTING

EX-d Explosionproof for Zone 1 & 2 Gas Groups IIA & IIB

Explosion proof of complete fan alongwith motor is certified by C M R I Dhanbad.

(A) CEILING FAN : FIRST TIME IN INDIA.
SUDHIR has developed First Time in India CEILING CAN suitable for Single Phase 240V AC supply in cast aluminium alloy LM6 construction light weight blade size upto 48". Cat. No. CF/193

(B) EXHAUST FANS:
Cat. No. EF/140 Single/Three Phase Size 9" to 24".

(C) WALL MOUNTING FANS :
Cat. No. WMF/140 Single/Three Phase Size 16" to 36".

(D) DEDESTAL FANS :
Cat. No. PF/140 Aircirculators/Mancoolers single/three phase size 12" to 36".

NOTE :- Fans with FRP Coating Stainless Steel Wire Guards, Blades or Specific application are also available.

Other Products in 'SUDHIR FLAMEPROOF EQUIPMENT' category
FLAMEPROOF JUNCTION BOX, GLANDS & TELEPHONE
FLAMEPROOF JUNCTION BOX, GLANDS & TELEPHONE
SUDHIR FLAMEPROOF SWITCHGEARS - Total Range
SUDHIR FLAMEPROOF SWITCHGEARS - Total Range
FLAMEPROOF PBS, DOL STARTERS & PLUG SOCKETS
FLAMEPROOF PBS, DOL STARTERS & PLUG SOCKETS
 
<< Back


 
 
 

 
Contact Details
SPOT TRADING CO.
3443, Gali Bajrang Bali, Chawri Bazar, Delhi - 110006, India
Phone:91-11-65172292/23255999/45637944
Fax:91-11-23255999
Send Mail  
Contact Now
Key Personnel
Mr. Ashish Garg (Partner)
Mobile:+919811123460, +919311123460